๐Ÿšจ

FIRE ALARM (LOC)

6522 LOWER YORK RD ยท Btwn: REEDER RD & SHIRE DR/

E46

ETA

4m

DIST

1.3mi

HYD

493ft

PREPLAN

N

PRIOR

10

Temp

72ยฐF

Wind

11 ENE

Conditions

Light rain

Humidity

93%

Prior Calls at This Address (9)

โš  FREQUENT ALARM LOCATION โ€” 5 of 9 priors were alarm activations ยท 3 in last 6 months ยท no actual fires

FIRE ALARM (LOC)7/3/2026
FIRE ALARM (LOC)4/11/2026
FIRE ALARM (LOC)2/12/2026
745 - Alarm system activation, no fire - unintentional12/28/2022
745 - Alarm system activation, no fire - unintentional8/1/2018
Show all 9 prior calls
611 - Dispatched & cancelled en route6/17/2017
324 - Motor vehicle accident with no injuries.11/1/2016
412 - Gas leak (natural gas or LPG)9/2/2015
412 - Gas leak (natural gas or LPG)2/16/2015
Hydrant GPM1500+1000+500+<500Unknown

Radio Size-Up

[UNIT] is on scene at CUGINIS ITALIAN KITCHEN,

1-story ordinary restaurant,

approximately 65 by 95,

nothing in evidence, out investigating.

Reference

Wind: 11mph ENE โ†’ fire spreads WSW

10 prior calls at this address

SB 10 โ€” 493ft SE โ€” 1000+ GPM

Mfr: AMERICAN DARLING | 70 PSI | Good Drain | Valve: 4' FRONT OF HYDRANT

Structure

Ordinary Restaurant w/ Liquor

Occupancy

Assembly

Footprint

6,166 sq ft

Construction

Ordinary

Google Street View

Dispatch

MAIN DINING SMOKE DET - W/N

Caller: 69 CITADEL

Water Supply

493ft

SE

LAY-IN1000+ GPM

Logan Square Village Run

Mfr: AMERICAN DARLING | 70 PSI | Good Drain | Valve: 4' FRONT OF HYDRANT

818ft

SE

ALT SUPPLY1000+ GPM

Logan Square Market Place

Mfr: AMERICAN DARLING | 70 PSI | Good Drain | Valve: 20' FRONT & 15' RIGHT OF HYDRANT

๐Ÿšจ Incident Snapshot

moderate

Fire alarm activation - main dining smoke detector

Restaurant with liquor license, 6,166 sq ft

5 prior alarms in 3.5 months โ€” nuisance pattern likely

โš ๏ธ Primary Risk Signals

Nuisance alarm history

5 activations since March โ€” high probability of cooking/HVAC false alarm

Confirm no active fire before committing resources

๐ŸŒฌ๏ธ Environmental Conditions

Wind 11 mph ENE, light rain

Smoke from kitchen will drift toward front/dining area

Visible smoke likely from stove/grill exhaust or detector sensitivity

๐Ÿ”ฅ Fire Behavior Cue

Kitchen-origin fire would be contained to hood/exhaust system if Ansul present and functioning

Ansul discharge may trigger secondary alarm โ€” expect white powder if system activated

โœ”๏ธ Confirm on Arrival

Smoke source

Visible smoke in dining area, kitchen, or exhaust hood โ€” location confirms kitchen vs structural fire

Hood/Ansul system

Confirm hood is operational and Ansul cartridge status โ€” white powder discharge indicates system activation

Occupancy

Number of occupants present, evacuation status, any injuries or complaints

Detector sensitivity

Smoke detector location and distance from kitchen โ€” false alarms often from proximity to cooking

๐Ÿง  Common Causes

Cooking exhaust or steam triggering hood detector

Ansul system test or cartridge discharge

High humidity + detector proximity to kitchen

Hood filter accumulation or exhaust blockage

Field Notes

NAVIGATE TO SCENE